Installation Instructions / Warranty Starck 10452181 Montreux 16549181
Axor Starck Free-standing Tub Filler Rough 10452181 This rough is for use with Axor Starck free-standing tub fillers 10458XX1, 10456XX1 and 10406XX1. If using Axor Montreux Rough 16549181, go to page 8.
Starck 10456XX1 Tub shown: HOESCH Philippe Starck Edition II Freestanding tub with outside covering.
Starck 10406001 Tub shown: Duravit Philippe Starck Starck X Freestanding tub with outside covering. 4 If clearance is less than 1 1/8“, order extension 97686000.
Technical Data Operating pressure: Recommended operating pressure: Test pressure: Hot water temperature: Recommended hot water temperature: 1/2“ NPT inlets max. 145 psi 14.5 - 72 psi 232 psi max. 176° F* 120° F - 140° F* These tub fillers are not anti-scald. If required by local plumbing code, install remote pressure balance valve 13418181 to the hot and cold supplies within 6‘ of the rough. *Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
Installation – 10452181 Use the rough as a template to mark the positions of the screw holes in the subfloor. Use an 8 mm bit to drill the holes. Install the anchors (included). Fasten the rough to the subfloor with the screws provided. Make sure that the rough is level. Wrap the threads on the supplies with Teflon thread tape. Install the supplies in the rough. For proper operation of the tub filler, the hot supply should be installed on the left, the cold supply on the right.
Replace and tighten the plugs (1). Pressure test the unit (2). Install the plaster shield. Use a 5 mm Allen wrench to tighten the screws. Install the flooring material. Please know and follow all applicable local codes regarding waterproofing. The surface of the finished floor must fall somewhere between the “minimum” and “maximum” markings on the plaster shield.
Axor Montreux Free-standing Tub Filler Rough 16549181 This unit is for use with Axor Montreux freestanding tub filler 16547XX1.
Technical Data Operating pressure: Recommended operating pressure: Test pressure: Hot water temperature: Recommended hot water temperature: max. 145 psi 14.5 - 72 psi 232 psi max. 176° F* 120° F - 140° F* This tub filler is not anti-scald. If required by local plumbing code, install remote pressure balance valve 13418181 to the hot and cold supplies within 6‘ of the rough. *Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
Installation – 16549181 Wrap the threads on the two plugs with Teflon thread tape. Install one plug on each rough. Use the mounting plate as a template to mark the positions of the screw holes in the subfloor. Use an 8 mm bit to drill the holes. Install the anchors (included). Fasten the roughs to the subfloor with the screws provided. Make sure that the roughs are level. Wrap the threads on the supplies with Teflon thread tape. Install the supplies in the roughs.
Remove the flush insert plug from the cold water side of the rough. Install a hose bibb and a hose. Turn on the water and allow the line to flush thoroughly. Repeat the flushing procedure on the hot water side. Replace and tighten the plugs. Pressure test the unit. Install the plaster shields. Use a 5 mm Allen wrench to tighten the screws.
Install the flooring material. Please know and follow all applicable local codes regarding waterproofing. The surface of the finished floor must fall somewhere between the “minimum” and “maximum” markings on the plaster shield.
Cleaning Recommendation for Hansgrohe Products Modern faucetry and shower products utilize a combination of materials to comply with the needs of the market with regard to design and functionality. To avoid damage, it is necessary to use some caution when cleaning. Damage caused by improper treatment is not covered under the Hansgrohe warranty. Cleaning Materials for Faucets and Showers • • • • To remove lime scale, use only products made specifically for that purpose.
Limited Lifetime Consumer Warranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada. WHO IS COVERED BY THE WARRANTY This warranty extends to the original consumer purchaser only. WHAT IS COVERED BY THE WARRANTY This warranty covers only your Hansgrohe manufactured product.
This warranty gives you specific legal rights, and you may have other rights which vary from State to State. You may be required by law to give us a reasonable opportunity to correct or cure any failure to comply before you can bring any action in court against us under the Magnuson-Moss Warranty Act. PRODUCT INSTRUCTIONS AND QUESTIONS Upon purchase or prior to installation, please carefully inspect your Hansgrohe product for any damage or visible defect.
www.hansgrohe-USA.com US - Installation Instructions • Part No. 90861903 • Revised 07/2006 Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 Tel.