Specifications

Assembly
18
Fig 39-40-41
K
Locking knob
Scale
Scale set to Zero
Step 9 Locate the extraction moulding (I), loosen the
two locking knobs (b) either side of the extraction
surround on the fence (H), slide the extraction
moulding (I) over the T’ bolts (d) and retighten the
locking knobs (b). (See fig 42)
WARNING! DO NOT OVERTIGHTEN
THE LOCKING KNOBS AS THE
EXTRACTION MOULDING IS ONLY
PLASTIC!
Fig 42
I
b
Step 10 Locate two T bolts (d), fence spacers (c) and
flat washers (i). Slide the T bolts into the fence (H) T’
slot and position the bolts roughly the width of the
extraction moulding (I) and place a fence spacer (c)
over the T’ bolt thread. (See figs 43-44)
Fig 43-44
H
d
c
Step 11 Mount the dust shield (J) through the T
bolts (d), place a flat washer (i) over the bolts and
secure using two locking knobs (b), see figs 45-46.