Specifications

SITE CONSIDERATIONS
General Condition:
1. Electrical connection: Steady state voltage: 0.9-1.1
of nominal voltage.
Frequency: 0.99-1.01 of nominal frequency
continuously; 0.98-1.02 short time
2. Altitude are not exceeding 1000m,
O
Maximum ambient air temperature is +40 C,
minimum ambient air temperature is not less than
O
+5 C,
Storage and transportion temperature range is
O O
Lighting and Outlets
-25 C+55 C.
The relative humidity does not exceed 50% at a
O
Lighting should be bright enough to eliminate shadow
maximum temperature of +40 C, higher relative
and prevent eye strain. Electrical circuits should be
humidity may be permitted at lower temperature
O
dedicated or large enough to handle combined motor
(e.g. 90%@ 20 C).
amp loads. Outlets should be located near each
machine so power or extension cords are not
obstructing high-traffic areas. Be sure to observe local
electrical codes for proper installation of new lighting,
Floor Load
outlets, or circuits.
This machine represents a moderately large weight
load in a small footprint. Most commercial shop floors
Dust Collector
will be adequate for the weight of the machine. Some
floors may require additional support. Contact an
As a rule, this machine must be vacuumed during use. A
architect or structural engineer if you have any question
time relayed socket is available as an accessory. In
about the ability of your floor to handle the weight.
addition, the vacuum performance must be sufficient to
achieve the required negative pressures and a
To ensure sufficient upright stability of the machine
maximum air speed of 20m/sec at the connector.
it should be bolted to floor. For this purpose 4 holes
are provided in the machine' s bracket of workstand.
Read the manual before assembly and operation.
Working Clearances
Become familiar with the machine and it's
operation before beginning any work. Serious
Working clearances can be thought of as the distances
personal injury may result if safety or operational
between machines and obstacles that allow safe
information is not understood or followed.
operation of every machine without limitation. Consider
existing and anticipated machine needs, size of
material to be processed through each machine, and
space for auxiliary stands and/or work tables. Also
consider the relative position of each machine to one
another for efficient material handling. Be sure to allow
yourself sufficient room to safely run your machines in
any foreseeable operation.
Consider existing and anticipated needs, size of
material to be processed through each machine, and
space for auxiliary stands, work tables or other
machinery when establishing a location for your saw.
See above figure for the maximum working clearances
of the Sliding Panel Saw.
The mains connection must have maximum16A fuse.
Electrical supply which has protection devices of
under-voltage, over-voltage, over-current as well as
a residual current device (RCD) which maximum
residual current rated at 0.03A.
3600mm
4