User Manual
7
REPLACING THE HEAD
You can switch out or replace the fluid head with the
included 3 mm hex key:
1. Use the 3 mm hex key to loosen (but not remove) the hex
set screw underneath the baseplate.
2. Rotate the head counterclockwise to remove it.
3. Seat the replacement head onto the mounting stud, and
rotate clockwise until secure.
4. Tighten the hex set screw underneath the baseplate.
If necessary, you can reverse the 1/4 in. or 3/8 in. mounting
stud to attach the head:
1. Loosen the baseplate’s top hex set screw.
2. Rotate the baseplate counterclockwise.
3. Remove and invert the stud, and screw it in with the base
until fully tightened.
4. Tighten the baseplate’s top hex set screw.