Tus neeg siv phau ntawv

Installationsanleitung AXIbox 11K
EN221129 12
Input terminal
overtemperature
Red on 3s, yellow on 1s, red flash 1 time,
yellow on 1s, red flash 2 times, yellow on 1s,
and so on
1. Check the surrounding conditions of
chargers installed whether there is heating
device nearby. Make sure environmental
temperature is under 60.
2. Check if the input terminals are in bad
contact
Relay
overtemperature
Red on 3s, yellow on 1s, red flash 2 times,
yellow on 1s, red flash 2 times, yellow on 1s,
and so on
Please contact our support
Under voltage fault
Red on 3s, yellow on 1s, red flash 3 times,
yellow on 1s, red flash 2 times, yellow on 1s,
and so on
1. Check the input voltage from the backend.
2. If the voltage is under 184Vac for a short
time, wait till the power grid recovers to
normal voltage range.
Over voltage fault
Red on 3s, yellow on 1s, red flash 4 times,
yellow on 1s, red flash 2 times, yellow on 1s,
and so on
1. Check the input voltage from the backend.
2. If the voltage is over 276Vac for a short
time, wait till the power grid recovers to
normal voltage range.
Overcurrent fault
Red on 3s, yellow on 1s, red flash 1 time,
yellow on 1s, red flash 3 times, yellow on 1s,
and so on
1. Shut off the leakage current protection
switch of power distribution cabinet
immediately.
2. Check whether there is low resistance
connection between AC output cables of the
charger.
Over frequency
fault
Red on 3s, yellow on 1s, red flash 2 times,
yellow on 1s, red flash 3 times, yellow on 1s,
and so on
1. Check the input voltage frequency from the
backend.
2. If the frequency exceeds 63Hz for a short
time, wait till power grid recover to normal
frequency range.
under frequency
fault
Red on 3s, yellow on 1s, red flash 3 times,
yellow on 1s, red flash 3 times, yellow on 1s,
and so on
1. Check the input voltage frequency from the
backend.
2. If the frequency is lower than 47Hz for
short time, wait till power grid recover to
normal voltage range.
Leakage detecting
circuit fault while
self-checkingl
Red on 3s, yellow on 1s, red flash 4 times,
yellow on 1s, red flash 3 times, yellow on 1s,
and so on
Check the connection of the CT port
Lock fault
Red on 3s, yellow on 1s, red flash 3 times,
yellow on 1s, red flash 4 times, yellow on 1s,
and so on