7 Troubleshooting
State
LED State
Solutions
Standby
Flashing green, 1s on, 3s off
Charging
Breathing green, 1s on, 1s off
Cable connected
Breathing yellow, 1s on, 1s off
Self check
Green 1s, Yellow 1s, Red 1s
Software upgrade
Green, fast flash
Ground warning
Flashing yellow, 2s on, 2s off
Check grounding contact
Relay fault
Red on 3s, yellow on 1s, red flash 1 time,
yellow on 1s, red flash 1 time, yellow on 1s,
and so on
Please contact our support
Input polarity
reverse
Red on 3s, yellow on 1s, red flash 2 times,
yellow on 1s, red flash 1 time, yellow on 1s,
and so on
1. Shut off the leakage current protection
switch of power distribution cabinet
immediately.
2. Check if AC input/output cables are normal,
and if inverse connection of L/N input cables.
CP fault
Red on 3s, yellow on 1s, red flash 3 times,
yellow on 1s, red flash 1 time, yellow on 1s,
and so on
Please contact our support
Leakage current
fault
Red on 3s, yellow on 1s, red flash 4 times,
yellow on 1s, red flash 1 time, yellow on 1s,
and so on
1. Shut off the leakage current protection
switch of power distribution cabinet
immediately.
2. Check whether there is broken of AC output
cables or low resistance connection to the
earth.