Installation and operation Manual AXIbox 11K
Installationsanleitung AXIbox 11K INDEX 1 TARGET GROUP OF THIS DOCUMENT .......................................................................... 3 2 GENERAL REGULATIONS AND SAFETY MEASURES ............................................... 3 3 DESCRIPTION OFT HE PRODUCT ................................................................................... 4 3.1 Function and intended use ......................................................................................................................
Installationsanleitung AXIbox 11K 1 Target group of this document This document refers to the assembly, installation and operation of the AXIbox 11K charging station and is intended for the installer and the users. Chapters 5-7 are intended exclusively for the charging station installer with the appropriate qualification. 2 General regulations and safety measures The input and output voltages of this unit are dangerous high voltages that can endanger human life.
Installationsanleitung AXIbox 11K The charging cable must not be kinked, pinched, run over or otherwise damaged. Keep children away from the charging station. The car must not be driven during charging. 3 Description oft he product 3.1 Function and intended use The AXIbox 11K is used for charging electric cars. There is a choice of two modes, which can be set during installation: In Plug & Play mode, no authentication by the user is necessary.
Installationsanleitung AXIbox 11K 4 Operation 4.1 Operation with Acces restriction In this operating mode, the wallbox is locked against unauthorised use. Authentication with one of the supplied RFID cards or control via App is required for operation. 4.1.1 Starting the charging process with RFID-Card 1. Connect the wallbox to the car to be charged via the cable. Make sure that the cable is completely unwound. The LED flashes yellow every 1 second. 2.
Installationsanleitung AXIbox 11K 4.2 Plug & Play mode No authentication is required in this operating mode. 4.2.1 Starting the charging process 1. Connect the wallbox to the car to be charged via the cable. Make sure that the cable is completely unwound. 2. Start the charging process on the vehicle. During the charging process, the LED flashes green every 1 second. 4.2.2 Ending the charging process 1. Stop the charging process at the car. When the car is fully charged, charging will stop. 2.
Installationsanleitung AXIbox 11K 5 Requirements 5.1 Electrical requirements When making the electrical connection, the country-specific regulations, standards and application rules must be observed. 5.1.1 Supply cable The power supply of the wallbox must be three-phase (3P + N + PE; min. 5 x 2,5 mm2, depending on the locally applicable regulations, environmental conditions and installation type). The required conductor voltage is 400 V AC and a current of 16 A per phase with 50 Hz mains frequency. 5.1.
Installationsanleitung AXIbox 11K 6 Installation Electrical device should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by the manufacturer for any consequences arising out of the use of this device. A qualified person is one who has skills and knowledge related to the construction, installation and operation of electrical device and who has received safety training to recognize and avoid the hazards involved.
Installationsanleitung AXIbox 11K 6.2 Setting the operating mode The AXIbox has two operating modes. The changeover may only be carried out by a specialist, taking into account all necessary safety precautions. 6.2.1 Control via RFID When delivered, the AXIbox is protected against unauthorised use by a lock. The charging process is started by the RFID cards supplied. If this operating mode is desired, no changes need to be made.
Installationsanleitung AXIbox 11K 6.3 Electrical installation The electrical supply to the wallbox is three-phase, a cable with 3 conductor phases, a neutral conductor and a PE conductor is required. Feed the cable through the left-hand opening at the bottom of the AXIbox housing. Clamp the wires of the cable into the terminals provided. Use the wire end ferrules supplied and fix the cable inside the AXIbox with the sleeve. Schematic representation of the wiring 6.
Installationsanleitung AXIbox 11K 7 Troubleshooting State LED State Solutions Flashing green, 1s on, 3s off Standby Breathing green, 1s on, 1s off Charging Breathing yellow, 1s on, 1s off Cable connected Green 1s, Yellow 1s, Red 1s Self check Green, fast flash Software upgrade Flashing yellow, 2s on, 2s off Ground warning Check grounding contact Relay fault Red on 3s, yellow on 1s, red flash 1 time, yellow on 1s, red flash 1 time, yellow on 1s, and so on Input polarity reverse Red on 3s, yellow on 1
Installationsanleitung AXIbox 11K Input terminal overtemperature Red on 3s, yellow on 1s, red flash 1 time, yellow on 1s, red flash 2 times, yellow on 1s, and so on 1. Check the surrounding conditions of chargers installed whether there is heating device nearby. Make sure environmental temperature is under 60℃. 2. Check if the input terminals are in bad contact Relay overtemperature Red on 3s, yellow on 1s, red flash 2 times, yellow on 1s, red flash 2 times, yellow on 1s, and so on 1.
Installationsanleitung AXIbox 11K 8 Disposal The AXIbox is subject to the EU Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE). The AXIbox must therefore not be disposed of with household waste, but must be disposed of in accordance with national and regional regulations for electrical and electronic equipment. The unit should be rendered inoperable before disposal.