User`s manual
AX2200/AX2300 Instruction Manual Chapter 1 Introduction
CM2-AX2200-2001 (Rev. 4, 4/2014) 1-9
Line Size / Process Connections / Materials
The AX2200 In-line model is built for line sizes ½ through 4 inch wafer
or ½ through 8 inch flanged design using ANSI 150, 300, 600, PN16, 40,
or 64 class flanges.
The AX2300 Insertion model can be used in line sizes 2 inch and greater
and is built with a compression fitting or packing gland design using 2
inch NPT, or 2 inch flanged connections (ANSI 150, 300, 600, PN16, 40,
or 64 class flanges). The packing gland design can be ordered with a
permanent or removable retractor.
The AX2200 In-line model can be built with A105 carbon steel, 316L
stainless steel, or Hastelloy C-276. The AX2300 Insertion model can be
built with 316L stainless steel or Hastelloy C-276.
Flow Meter Electronics
AX2000Series Flow Meter electronics are available mounted directly to
the flow body, or remotely mounted. The electronics housing may be
used indoors or outdoors, including wet environments. Available input
power options are: DC loop powered (2-wire), DC powered, or AC pow-
ered. Three analog output signals are available for your choice of three
of the five process variables: mass flow rate, volumetric flow rate, tem-
perature, pressure or fluid density. A pulse output signal for remote to-
talization and MODBUS or HART communications are also available.
AX2000Series Flow Meters include a local 2 x 16 character LCD display
housed within the enclosure. Local operation and reconfiguration is ac-
complished using six pushbuttons operated via finger touch. For hazard-
ous locations, the six buttons can be operated with the electronics enclo-
sure sealed using a hand-held magnet, thereby not compromising the in-
tegrity of the hazardous location certification.
The electronics include nonvolatile memory that stores all configuration
information. The nonvolatile memory allows the flow meter to function
immediately upon power up, or after an interruption in power.
All
flowmeters are calibrated and configured for the customer’s flow
application.