User`s manual
Series AX2200/AX2300 Instruction Manual Appendix A Specifications
CM2-AX2000-2001 (Rev. 4, 4/2014) A-5
User is responsible for the provision of an external Disconnect
Means (and Over-Current Protection) for the equipment (both AC
and DC models).
Display Alphanumeric 2 x 16 LCD digital display.
Six push-button switches (up, down, right, left, enter, exit) operable
through explosion-proof window using hand-held magnet. Viewing
at 90-degree mounting intervals.
Pocess Fluid and Process Fluid:
Ambient Temperature Standard temperature sensor: –330 to 500° F (–200 to 260°C)
High temperature sensor: to 750° F (400° C)
Ambient:
Operating temperature range: –40 to 140° F (–40 to 60° C)
Storage temperature range: –40 to 185° F (–40 to 85° C)
Maximum relative humidity: 0-98%, non-condensing conditions
Maximum altitude: -2000 to 14,000 feet (-610 to 4268 meters)
Pollution Degree 2 for the ambient environment
Output Signals
(1)
Analog: Volumetric Meter: field rangeable linear 4-20 mA output
signal (1200 Ohms maximum loop resistance) selected by user for
mass flow rate or volumetric flow rate.
Communications: HART, MODBUS, RS485, BACnet
Multiparameter Meter: up to three field rangeable linear 4-20 mA
output signals (1200 Ohms maximum loop resistance) selected
from the five parameters–mass flow rate, volumetric flow rate, tem-
perature, pressure and density.
Pulse:Pulse output for totalization is a 50-millisecond duration pulse
operating a solid-state relay capable of switching 40 VDC, 40 mA
maximum.
Note: (1) All outputs are optically isolated and require external power
for operation.
Alarms Up to three programmable solid-state relays for high, low or window
alarms capable of switching 40 VDC, 40 mA maximum.
Totalizer Based on user-determined flow units, six significant figures in scien-
tific notation. Total stored in non-volatile memory.
Wetted Materials AX2200 In-Line Flow Meter:
316L stainless steel standard.
C276 hastelloy or A105 carbon steel optional.
AX2300 Insertion Flow Meter:
316L stainless steel standard.
Teflon
®
packing gland below 500° F (260° C).
Graphite packing gland above 500° F (260° C).
Enclosure Protection
Classification NEMA 4X and IP66 cast enclosure.
Electrical Ports Two 3/4-inch female NPT ports.
Mounting Connections AX2200: Wafer, 150, 300, 600 lb ANSI flange, PN16, PN40, PN64
flange.
AX2300 Permanent installation: 2-inch MNPT; 150, 300, 600 lb ANSI
flange, PN16, PN40, PN64 flange with compression fitting probe
seal.
AX2300 Hot Tap
(1)
Installation: 2-inch MNPT; 150, 300, 600 lb ANSI
flange, PN16, PN40, PN64 flange and optional retractor with pack-
ing gland probe seal.
Note: (1) Removable under line pressure.