User manual
AXIS Q7424–R
Technical Specifications
Connectors
I/O terminal connector
6–pin terminal block for:
• Digital Input
• Digital Output
• Auxiliary power and ground (GND)
1 2 3 4 5 6
Function Pin Notes
Specifications
GND
1
Ground
12V DC Power
2
Can be used to pow er auxiliary equipment.
Note: This pin can only be used as power out.
Max load = 125 m A
Digital input — Connect to GND to activate, or leave floating
(unconnected) to d eactivate.
0to+30VDCConfigurable
(Input or Output)
3–6
Digital output — Internal connection to ground when
activated, floating (unconnected) when deactivated. If
used with an inductive load, e.g. a relay, a diode must be
connected in parallel with the load, for protectio n against
voltage transients.
Max load =100 mA
Max voltage = + 30 V DC
1
2
E.g. push button
3
4
12 V
max. 125mA
D
S
G
55