Events
Events
The Axis product can be congure d to perform actions whe n di ffe rent e ve nts occur, for example, start a rec ord ing w he n motion is
detected. The set of conditions that denes how and when the action is triggered is called an Action Rule.
Available Action Rule triggers and conditions include :
Applications use installed a pplications to trigger the r u le, see
Applications, on page 28
.
Detectors
- Audio Detection trigger the rule when audio is detected, see
Audio Detection, on page 30
.
- Motion Detection trigger the rule when motion is detected, see
Motion Detection, on page 29
.
- Tampering trigger the rule when tampe ring is detected, see
Camera Tampering, on page 29
.
Hardware
- Video Signal trigger the rule if video s ignal is lost.
- Network trigger the rule if network connection is lost o r restored. This can for example be used to start
recording to the SD card.
Input Signal
- Digital Input Port trig ger the rule when an I/O port receives a signal from a connected device, see
I/O
Ports, o n page 44
.
- Manual Trigger trigger the rule using the Manual Trigger button in the Live View page, see
Controls on the
Live View Page, on page 9
. This can for example be used to validate actions d
uring pro duct installation
and conguration.
PTZ
- Moving trigger the rule when the cam era view m oves due to a PTZ operation. This can for example be used
as an additi onal condition to prevent an action rule triggered by motion detectio n to record video while the
camera view m oves due to a P TZ operation.
- Preset Reached —triggertheru
le when the camera stops at a preset position. This can be for example be used
with the Send Images action to upload images from the preset position.
Storage
- Available trigger the rule when the storage device is unmounted or removed. This can for example be
used to send maintenance no tications.
- Full trigger the rule when the s torag e device is full. Under normal opera tion, the oldest recor dings will be
overw
ritten to prevent the storage de vice from becoming full.
- L
ocked trigger the rule if the storage device is locked (write protected).
- Storage read only —thele system is broken or the lock switch on the SD card is in locked position
System
- System Initializing trigger the rule when the product is being starte d. This can for example be used to send a
notication when the pro duct restarts.
Time
- Recurrence trigger the rule periodically, see
Recurrences, on page 33
. This can for example be used to
upload an image eve ry 5 minutes.
31