User`s manual

42
AXIS Q7404 - Unit connectors
The following connection diagram gives an example of how to connect an auxiliary device to the AXIS Q7404.
RS-485/RS-422 connector - For each video channel, AXIS Q7404 has two 2-pin terminal blocks for the RS-485/RS-422
serial interface used to control auxiliary equipment, e.g. PTZ devices.
The RS-485/RS-422 serial port can be configured in the following port modes:
Bidirectional RS-485 half-duplex port for data transmission using two wires, one combined RX/TX
pair.
Bidirectional RS-485 full-duplex port for data transmission using four wires, one RX pair and one
TX pair.
Unidirectional RS-422 port for transmitting or receiving data using two wires, RX- or TX pair.
Bidirectional RS-422 full-duplex port for data transmission (point-to-point) using four wires, one
RX pair and one TX pair.
Function Pin Notes
RS-485A alt RS-485/422RX(A) 1 RX pair for all modes (combined RX/TX for 2-wire RS-485)
RS-485B alt RS-485/422RX(B) 2
RS 485/422TX(A) 3 TX pair for RS-422 and 4-wire RS-485
RS 485/422TX(B) 4
E.g. push button
I/O congured as input
I/O congured as output
AXIS Q7404
3.3V
3.3V max 250mA
D
S
G
1
234
RX/TX
TX