User`s manual
41
AXIS Q7404 - Unit connectors
Unit connectors
Network connector - RJ-45 Ethernet connector. Shielded Cat-5e or Cat-6 cables are recommended.
Power connector - Power input. Use the supplied power adapter or an external power supply 8-20V DC, max.
16.1W.
Video inputs - AXIS Q7404 supports four video sources (VIDEO 1 - VIDEO 4). Each video input is terminated using a coax/BNC
connector. Use a 75 ohm coaxial video cable; recommended maximum length is 250 meters (800 feet).
Note:
If the video source is to be connected in parallel with other equipment using a BNC T adaptor, disable the input termi-
nation by setting the 75 ohm termination switch to OFF. Failure to do so may cause reduced image quality.
Audio connectors - AXIS Q7404 has two audio connectors connected to video channel 1:
• Audio in – 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).
• Audio out – 3.5 mm output (line level) that can be connected to a public address (PA) system or an active speaker
with a built-in amplifier. A pair of headphones can also be attached. A stereo connector must be used for the audio
out.
I/O terminal connector - Used in applications for e.g. motion detection, event triggering, time lapse
recording and alarm notifications. The AXIS Q7404 has 2 configurable inputs/outputs per video channel.
These provide the physical interface to:
• Digital output - For connecting external devices such as relays and LEDs. Connected devices can be
activated by VAPIX®, output buttons on the Live View page or by an Event Type. The output will show
as active (shown under Events > Port Status) if the alarm device is activated.
• Digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for example:
PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes
active (shown under Events > Port Status).
Pin assignments:
Function Pin number Description
GND 1 Ground
DC Power 2 Power input 8-20V DC, max 16.1W
Function Pin number Notes Specifications
GND 1 Ground
3.3VDC Power 2 Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Max load = 250mA
Configurable
(Input or Out-
put)
3 - 4 Digital input - Connect to GND to activate, or leave floating (or uncon-
nected) to deactivate.
Min input = - 40V DC
Max input = + 40V DC
Digital output - Uses an open-drain NFET transistor with the source con-
nected to GND. If used with an external relay, a diode must be connected
in parallel with the load, for protection against voltage transients.
Max load = 100mA
Max voltage = + 40V DC
1
2