User manual

AXIS Q6032-E PTZ Dome Network Camera
Events
Events
The Axis p roduct can be congured to perform actions when different events occur, for example, start a re c ording when motion is
detected. The set of conditions that denes how and when the action is triggered is called an Action Rule.
Available Action Rule triggers and conditions include:
Applications use installed applications to trigger the rule, see
Applications, on page 30
.
Detectors
- Motion Detection trigger the rule when motion is detected, see
Motion Detection, on page 28
.
Hardware
- Open Casing Detection trigger the rule if the casing of a connected external device, such as a junction
box or cabinet (not included), is removed or opened. This can for example be used to send notications of
maintenance or unauthorized tampering.
- Fan trigger the rule if the fan is malfunctioning. Thiscanforexamplebeusedtosendmaintenance
notications.
- Heater tri gger the rule if the heater is malfunctioning. This can for example be used to send maintenance
notications.
- Network trigger the rule if network connection is lost or restored. This can for exam ple be used to start
recording to the SD card.
Input Signal
- Manual Trigger trigger the rule using the Manual Trigger button in the Live View page, see
Controls on the
Live View Page, on page 8
. This can for example be used to validate a ctions d
uring product installation
and conguration.
PTZ
- Autotracking trigger the rule when autotracking starts or stops, see
Autotracking, on page 23
.
- Moving trigger the rule when the camera view moves due to a PTZ operation. This can for example be used
as an additional condition to prevent an action rule triggered by motio n detection to record video while the
camera view moves due to a PTZ op
eration.
- Preset Reached —trigger
therulewhenthecamerastopsatapresetposition.Thiscanbeforexamplebeused
with the Send Images action to upload images from the preset position.
Storage
- Available trigger the rule when the storage device is unmounted or removed. This can for example be
used to send maintenance notications.
- Full trigger the rule when the storage device is full. Under normal operation, the oldest recordings will b e
o
verwritten to pre vent the storage device from becoming full.
- Locked —triggertheruleifthestoragedeviceislocked(writeprotected).
System
- System Initializing trigger the rule when the product is being s tarte d. This can for example be used to send a
notication when the product restarts.
Time
31