User manual

AXISQ2901-ETemperatureAlarmCamera
HardwareOverview
Input/Output(I/O)devices
Whenconnectingexternalequipment,amulti-connectorcable(availablefromAxis)isrequiredinordertomaintaintheproduct’sIP
rating.Formoreinformation,seeMulti-ConnectorCable(soldseparately)onpage58.
PowerConnector
2-pinterminalblockforpowerinput.UseaSafetyExtraLowVoltage(SELV)compliantlimitedpowersource(LPS)witheitherarated
outputpowerlimitedto100Woraratedoutputcurrentlimitedto5A.
SDCardSlot
NO NO
NO
TICE TICE
TICE
RiskofdamagetoSDcard.DonotusesharptoolsorexcessiveforcewheninsertingorremovingtheSDcard.
Riskofdataloss.Topreventdatacorruption,theSDcardshouldbeunmountedbeforeremoval.Tounmount,gotoSetup>
SystemOptions>Storage>SDCardandclickUnmount.
ThisproductsupportsmicroSD/microSDHC/microSDXCcard(notincluded).
ForSDcardrecommendations,seewww.axis.com
ControlButton
Forlocationofthecontrolbutton,seeHardwareOverviewonpage6.
Thecontrolbuttonisusedfor:
Resettingtheproducttofactorydefaultsettings.Seepage57.
ConnectingtoanAXISVideoHostingSystemservice.Seepage49.Toconnect,pressandholdthebuttonforabout3
secondsuntiltheStatusLEDashesgreen.
ConnectingtoAXISInternetDynamicDNSService.Seepage49.Toconnect,pressandholdthebuttonforabout3seconds.
LEDIndicators
Note
TheStatusLEDcanbeconguredtoashwhileaneventisactive.
TheStatusLEDcanbeconguredtoashforidentifyingtheunit.GotoSetup>SystemOptions>Maintenance.
StatusLED
Indication
GreenConnectionandnormaloperation.
Amber
Steadyduringstartup.Flashesduringrmwareupgrade.
Amber/RedFlashesamber/redifnetworkconnectionisunavailableorlost.
RedFlashesredforrmwareupgradefailure.
7