User Manual
AXIS M5525-E PTZ Network Camera
Specifications
GND AUDIO IN Ground audio in
AUDIO OUT
Line audio out
GND AUDIO OUT Ground audio out
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital input - For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Digital output - For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface or in the product’s webpage.
6–pin terminal block. See Product overview on page 3 .
Function Pin Notes
Specications
0 V DC (-)
GND DC ground 0 V DC
DC output
12 V
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 V DC
Max load = 50 mA
Digital input – Connect to pin GND to activate, or leave oating
(unconnected) to deactivate.
0 to max 30 V DCCongurable
(Input or Output)
I/O
1–4
Digital output – Internally connected to pin 1 (DC ground) when
active, and oating (unconnected) when inactive. If used with an
inductive load, e.g. a relay, a diode must be connected in parallel
with the load, for protection against voltage transients.
0 to max 30 V DC, open drain,
100 mA
Power connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant
limited power source (LPS) with either a rated output power limited to ≤100 W or a rated output
current limited to ≤5 A.