User`s guide

AXIS 5470e User’s Guide 49
Using the Test Button
The following operations can be performed by pressing the test button in different
sequences. Please refer to Product Overview on page 4, to identify the location of the test
button.
Printing a test page:
Press the test button once to print a test page.
Printing the parameter list:
Press the test button twice to print the parameter list.
Resetting the AXIS 5470e parameters to the factory default settings:
1.Remove the external power supply to switch off the AXIS 5470e.
2.Press and hold down the test button, while you reconnect the external power sup-
ply. Continue to hold down the test button until the network indicator starts to flash
at one second intervals. This should take about 5 seconds.
3.Release the test button and wait until the network indicator flashes at least five
times.
4.Press and hold down the test button again until the network indicator remains
constantly lit.
5.Restart the AXIS 5470e by disconnecting and reconnecting the external power
supply.
Note:
Please refer to the User’s Manual for more information about the test button.
All parameters except the node address (NODE_ADDR.), the IP address (IP_ADDR.) and DHCP enabled or
disabled (DHCP_ENABLE.) are reset.