User manual

AXISP5635–EPTZDomeNetworkCamera
TechnicalSpecifications
-/+
~
+/ -
~
FunctionPinNotes
Specications
AC/DCPower
input
Polar-
ityin-
depen-
dent
UseaSafetyExtraLowVoltage(SELV)compliantlimited
powersource(LPS)witheitheraratedoutputpowerlimited
to≤100Woraratedoutputcurrentlimitedto≤5A.Ground
forAC/DC
24VAC/DC
Audioconnector-4–pinterminalblockusedforaudioinandaudiolineout.Thiscanbeconnectedtoapublicaddress(PA)system
oranactivespeakerwithabuilt-inamplier.
FunctionPinNotes
AudioIn
1
Balancedorunbalancedinputforamonomicrophoneorlinesignal
AudioLineOut
3
Canbeconnectedtoapublicaddress(PA)systemoranactivespeakerwithabuilt-in
amplier
GND
2,4
Ground
I/Oconnector-6–pinterminalblock.Usewithexternaldevicesincombinationwith,forexample,tamperingalarms,motion
detection,eventtriggering,timelapserecordingandalarmnotications.Inadditiontothe0VDCreferencepointandpower(DC
output),theI/Oconnectorprovidestheinterfaceto:
DigitaloutputForconnectingexternaldevicessuchasrelaysandLEDs.Connecteddevicescanbeactivatedbythe
VAPIX®ApplicationProgrammingInterface,outputbuttonsontheLiveViewpageorbyanActionRule.Theoutput
willshowasactive(shownunderSystemOptions>Port&Devices>PortStatus)ifthealarmdeviceisactivated.
DigitalinputAnalarminputforconnectingdevicesthatcantogglebetweenanopenandclosedcircuit,for
example:PIRs,door/windowcontacts,glassbreakdetectors,etc.Whenasignalisreceivedthestatechangesand
theinputbecomesactive(shownunderSystemOptions>Port&Devices>PortStatus).
1 2 3 4 5 6
FunctionPinNotes
Specications
DCOutput
2
Canbeusedtopowerauxiliaryequipment.
Note:Thispincanonlybeusedaspowerout.
12VDC
Maxload=50mA
GND
1
Ground
DigitalinputConnecttopin8toactivate,orleave
oating(unconnected)todeactivate.
0tomax30VDC Congurable
(InputorOutput)
3I/O1
4I/O2
5I/O3
6I/O4
DigitaloutputConnectedtopin8whenactivated,
oating(unconnected)whendeactivated.Ifusedwithan
inductiveload,e.g.arelay,adiodemustbeconnected
inparallelwiththeload,forprotectionagainstvoltage
transients.
0tomax30VDC,opendrain,
100mA
66