User manual
AXIS M1144–L
System Options
The log levels for the System Log and the Access Log are set under System Options > Support > Logs & Reports > Configuration.
The Access Log can be configured to list all connections to the product (select Critical, Warnings & Info). If required, a different log
level can be used wh e n sending emails.
Advanced
Scripting
Scripting allow s experienced users to customize and us e their o wn scripts.
NOTICE
Improper use may cause unexp ected behavio r and loss of contact with the Axis product.
Axis strongly recomm ends that you do not use this function unless y ou understand the consequences. Axis Support does no t provide
assistance for problems with customized scripts.
To open the Script Editor, go to System Options > Advanced > Scripting. It is recommended to create a backup file before
customizing the scripts. If a script causes problem s , reset the product to its factory de fa ult settings , se e
page 44
.
For more information, see www.axis.com/developer
File Upload
Files, for example web page s and images, can be uploaded to the Axis product and used as custom settings. To upload a file, g o
to System Options > Advanced > File Upload.
Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the
selected user group (viewer, operator or administrator) for the uploaded file.
Plain Config
Plain C on fig is for advanced users with experience of Axis product confi guration. Most parameters can be set and modified from this
page. Help is available from the standard help pages.
To open Plain Config, go to System Option s > Advan c ed > Plain Config .
Reset to Factory Default Settings
This will re se t all param ete rs , including the IP address, to the factory default settings :
1. Disconnect power from the product.
2. Press and ho ld the Control b utton and reconnect power (see
Hardware Overview on page 4
).
3. Keep the C ontrol b utton pressed for about 15 seconds until the Status indicator flashes amber.
4. Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The
product has been reset to the factory default settings. The default IP address is 192.168.0.90
5. Re-assign the IP address.
It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.
44