User`s manual

Appendix A: The Parameter List
78 Axis AFP User’s Manual
#500 Intervention Time-out
3270/Coax only Defines the time in minutes after which intervention required is sent to the host
after conditions such as paper out.
Note: 1. This parameter emulates an IBM 3812/3816 front panel switch: Suppress
Timeout on No-Data-Loss Intervention Required (IR).
#501 Early Print Complete
3270/Coax only Early Print Complete (EPC) enables the printer to give the host advance notice of
job completion before the page reaches the tray. This may increase the through-
put.
Notes: 1. This parameter has only effect in non-IPDS modes.
2. When using EPC, print data may be lost in abnormal situations.
3. This parameter emulates an IBM 3812/3816 front panel switch: Early Print
Complete (EPC) Response Timing.
Value
Description
0
Intervention Required (IR) is never sent to the host.
1 - 999
IR status is sent after the time speciÞed in minutes.
* 10
Factory default value. (10 minutes)
Value
Description
* No
Early Print Complete is inactive. (default)
Ye s
Early Print Complete is active.