User`s manual

Appendix C: The Front and Back Panels
126 Axis AFP User’s Manual
Error Messages
The following error messages can be displayed by the Axis AFP front panel indi-
cators:
1.Communication hardware error
2.NVRAM checksum error
3.RAM error
4.EPROM error
Notes: m means ‘off’, means ‘on’, and means ‘flashing’.
Indicators Case of error/action to be taken
SYSTEM
The Axis AFP cannot communicate with the Control Unit.
m READY
Contact your dealer for repair.
m DATA
m STATUS
ERROR
Indicators Case of error/action to be taken
SYSTEM
The non-volatile memory contents have been corrupted. All
m READY
parameters are reset to factory default settings. Power off, and
DATA
power on again to clear this message.
m STATUS
Note: This message always occurs at the first power on after a
ERROR
firmware upgrade.
Indicators Case of error/action to be taken
SYSTEM
Contact your dealer for repair.
READY
m DATA
m STATUS
ERROR
Indicators Case of error/action to be taken
SYSTEM
Contact your dealer for repair.
READY
(If you have replaced the EPROMS, make sure that they are
DATA
correctly placed into their respective sockets)
m STATUS
ERROR