#3290 Job Time-out
Defines the time-out value after which the host input PostScript job will be ended.
The timer starts from when there is no host data and the printer is ready. Used in
printing applications that demand the PostScript job to be ended, such as when
sharing a multi-port printer with other devices or when printing to a print server.
Notes: 1. A PostScript End-of-Job code (Ctrl-D) is sent to the printer after the time-out
has expired. When next host job is started, the prologue and previously down-
loaded resources are sent to the printer prior to the job.
2. Other hosts sharing the printer will get access to the printer according to the
printer’s PostScript default time-outs.
3. Setting a short Job Time-out value, may slow down overall print performance
as the prologue and previous resources, such as loaded fonts, need to be re-
loaded between printouts when the time-out has expired.
Related parameters: #3015 Job Separation
#3291 Job Begin String
#3292 Job End String
#3291 Job Begin String
Contains a hexadecimal string which is sent to the printer when a PostScript print
job is started.
Note: 1. The maximum number of bytes programmed into this string is 16 kbytes.
Related parameters: #3292 Job End Time-out
Value
Description
0
Disabled. No PostScript End-of-Job is sent to the printer.
1 - 1000
Time-out value in seconds.
* 10
Factory default value.
Value
Description
<any string>
Printer control commands.
* <empty>
Nothing is sent. (default)