User`s manual
Appendix A: The Parameter List
Axis AFP User’s Manual 117
#3211 Transparency Trailer String
3270/Coax only When this string is encountered in the hex transparency data stream, the transpar-
ency function will terminate, and the PostScript conversion is re-initialized.
Notes: 1. When this string is received, a new PostScript job will be initialized.
2. If anything else but hex transparency data is received between the Transpar-
ency Lead-in and Trailer Strings, an error message will be printed.
3. This string must be given as EBCDIC character codes.
4. The maximum string length is 8 bytes.
Related parameters: #3210 Transparency Lead-in String
#3280 Host Time-out
Defines the time-out value for which the coax or twinax input port will wait for
the next data before any other input port can have access to the printer.
Value
Description
<any string>
Transparency Trailer String (1 - 8 EBCDIC character codes).
* <empty>
Transparency function disabled. (default)
The transparency function can only be used in non-IPDS mode.
Value
Description
0
Disabled. The coax input cannot receive data.
1 - 1000
Time-out value in seconds.
* 10