User`s manual

Appendix A: The Parameter List
110 Axis AFP User’s Manual
#3003 Vertical Scale Factor
Enables vertical scaling of the complete page for all input bins. The parameter can
be set to compress or enlarge the size of the printed data on the paper. The scaling
is made relative the origin of the paper in the upper left corner.
Notes: 1. This parameter is valid in all modes, including local function listings, such as
the parameter list and IBM hex dump.
2. The vertical scaling is always parallel to the paper feed direction, regardless of
the print orientation.
3. Using this parameter to enlarge or compress the size of the printout may
result in interference patterns in images, due to the scaling.
4. A scale factor below 90% disables Load Font Smoothing.
5. The global vertical scaling may be overridden for individual input bins by
specifying a local vertical scale factor for one or more bins.
Hints: 1. Use a small compression, 98% for example, to get print data out of any
unprintable area at the top or bottom paper edges. Compensate for any
needed margin increase with the Bind Top Origin parameter.
2. If there is a requirement for 240 dpi direct printing for proof reading, 80%
scaling on a 300 dpi printer will provide a 1:1 dot-by-dot image.
Value
Description
1 - 999
Vertical scale factor (in percent).
* 100
Factory default value. (No scaling)
Related parameters: #1006 Bin 1 Vertical Scale Factor
#3002 Horizontal Scale Factor
#3011 Load Font Smooting