User`s manual

Section 3: Setting Up - SNA
AXIS 570/670 MIO User’s Manual 45
SNA
Host Set-up - IBM AS/400, 5250 CU mode
Before you begin
You have decided that the AXIS 570/670 MIO is going to run in
5250 CU mode, to provide optimum AS/400 performance.
Automatic Set-up
This setup procedure is based on the OS/400 autoconfiguration
feature. Full autoconfiguration support requires OS/400 Version 3
Release 1 or higher. If you have an earlier release than this, refer to
Manual Set-up, on page 47.
Make sure that the SYSVALs QAUTOCFG and QAUTORMT are
enabled. To enable automatic configuration of the APPC-controller,
set AUTOCRTCTL to *YES in the line description. Also make sure
the user QUSER has enough memory space allocated, *NOMAX is
recommended.
Setting Parameters
Prior to attempting autoconfiguration, the following Parameters must
be correctly set in the Print Server:
DEVICE_EMUL must be set to 5494
H1_ADDR must be set to the MAC address of the host
H1_LU_NAME must be set to the host system LU name
H1_NW_NAME must be set to the host system Network Name
AUTODIAL must be set to YES in order to activate
autoconfiguration.
These parameters are explained in detail in the AXIS 570/670 MIO
Set-up, on page 61.
Printer Device
Descriptions
Through autoconfiguration, the APPC controller, APPC device, RWS
controller as well as printer device descriptions for the logical printers,
will be created automatically.