Test Mode
Test Mode is reached from normal print operation. It is used to access
a number of internal functions. Normal print operation is inhibited.
Set the rotary switch to position ‘9’. When the SYSTEM indicator
starts to flash, you can select one of the following Test Mode
functions:
Do not forget to set the rotary switch to the device address again for
normal print operation. Switch the AX-3 Cobra+ off and on.
Pos. Test Mode Function
0
Restart
- same as power off/power on.
1
Set Factory Defaults
- abandon the current configuration.
2
Print Character Translation Table
- see Appendix B.
3
ASCII Hex Dump Mode
- trap the outgoing data stream
and print characters and control commands as hexadecimal
values.
4
System Hex Dump Mode
- trap the incoming data stream
and print characters and control codes as hexadecimal values.
5, 6 Reserved
7
Configuration from a Terminal
- run the Configuration
Utility, see Section 3.
8
Print Parameter List
- print the complete configuration, see
Appendix A.
9
Exit Test Mode
- resume normal print operation.