Section 4: Advanced Functions
36 AXIS AX-3 Cobra+ User’s Manual
Configuration and Transparency Sequences
The Start and Stop Transparency and Configuration are controlled by
three string parameters:
• Transparency Lead-In Sequence (#041), empty by default.
• Configuration Lead-In Sequence (#042), empty by default.
• Transparency/Configuration Trailer Sequence (#043), empty by
default.
See page 68 for a description of the parameters.
Define the Sequences
The parameters are defined when Extended Emulation Mode is
entered.
Example:
Enter Extended Emulation Mode and set the Transparency
Lead-In Sequence to ‘%%’, the Configuration Lead-In Sequence
to ‘%P’ and the Trailer Sequence to ‘%’:
Redefine the
Sequences
The parameters can be redefined using text sequences in the
document.
Example:
Change the Transparency Lead-In Sequence from ‘%%’ to ‘!?<’
(EBCDIC codes $4F,$6F,$4C).
Also, change the Trailer Sequence from ‘%’ to ‘>&’ (EBCDIC
codes $6E,$50):
&&??%%P
(Enter Extended Emulation Mode and set parameters)
%P
(Configuration lead-in sequence)
=41,$4F,$6F,$4C
(Change the transparency lead-in seq. to ‘!?<’)
=43,$6E,$50
(Change the configuration trailer seq. to >&’)
=205
(Save settings permanently)
>&
(Configuration trailer seq. (new))