5.11 Local digital input/output configuration
The Digital I/O window can be used to setup other digital I/O on the NextMove e100.
5.11.1 Digital input configuration
The Digital Inputs tab allows you to define how each digital input will be triggered, and if it should
be assigned to a special purpose function such as a Home or Limit input. There is one <- Axis x
row for each local axis configured in section 5.5.3. In the following example, digital input 1 will be
set to trigger on an active low input, and allocated to the forward limit input of axis 0:
1. In the Toolbox, click the Digital I/O icon.
2. At the bottom of the Digital I/O screen, click
the Digital Inputs tab.
The left of the screen shows a column of
yellow icons - High, Low, Rising, Falling and
Rise/Fall. These describe how the input will
be triggered.
3. Drag the Low icon
onto the IN1 icon . This will setup IN1 to respond to a low input.