Specifications
www.baldormotion.com
Input / Output 4-3MN1941
4.2 Analog I/O
The NextMove e100 provides:
H Two 12-bit resolution analog inputs.
H Four 12-bit resolution analog outputs.
4.2.1 Analog inputs
The analog inputs are available on connector X12, pins 1 & 2 (AIN0) and 4 & 5 (AIN1).
H Differential inputs.
H Voltage range: ±10 V.
H Resolution: 12-bit with sign.
H Input impedance: 120 kΩ.
H Sampling frequency: 4 kHz maximum, 2 kHz if both inputs are enabled.
The analog inputs pass through a differential buffer and second order low-pass filter with a cut-of f
frequency of approximately 1 kHz.
Both inputs are normally sampled at 2 kHz. However, an input can be disabled by setting
ADCMODE to 4 (_acOFF). With one input disabled, the remaining input will be sampled at 4 kHz.
In Mint, analog inputs can be read using the ADC keyword. See the Mint help file for full details of
ADC, ADCMODE and other related ADC... keywords.
NextMove e100
-
+
AIN0+
AIN0-
AGND
Mint
ADC(0)
-
+
2
3
1
+15 V
-15 V
‘X12’
Figure 2 - Analog input, AIN0 shown
For differential inputs connect input lines to AIN+ and AIN-. Leave AGND unconnected.