Installation Instructions
Page 12 AXIS S1032/AXIS S1048 Installation Guide
Physical:
Environmental:
Temperature
AXIS S1032 AXIS S1048
Height 42.8 mm (1.68 inch) 86.8 mm (3.41 inch)
Width With rack latches 482.4 mm
(18.99 inch)
Without rack latches 434.0
mm (17.09 inch)
With rack latches 482.4 mm
(18.99 inch)
Without rack latches 434.0
mm (17.09 inch)
Depth (excludes bezel) 607.0 mm (23.9 inch) 646 mm (25.4 inch)
Weight 13.6 kg (30.0 lb) 18.9 kg (41.7 lb)
AXIS S1032 AXIS S1048
Operating Continuous operation: 10 °C
to 35 °C at 10% to 80%
relative humidity (RH), with
26 °C max dew point. De-rate
maximum allowable dry bulb
temperature at 1 °C/300 m
above 900 m (1°F per 550 ft).
Note:
For information on
supported expanded
operating temperature
range and configura-
tions, see sup-
port.dell.com/
manuals.
Continuous operation: 10 °C
to 35 °C at 10% to 80%
relative humidity (RH), with
29 °C max dew point. De-rate
maximum allowable dry bulb
temperature at 1 °C/300 m
above 950 m (1°F per 550 ft).
Note:
For information on
supported expanded
operating temperature
range and configura-
tions, see sup-
port.dell.com/
manuals.
Storage –40 °C to 65 °C (–40 °F to 149
°F) with a maximum
temperature gradation of 20
°C per hour
–40 °C to 65 °C (–40 °F to 149
°F) with a maximum
temperature gradation of 20
°C per hour