Manual
25
Scheduled maintenance
NOTE: All maintenance work should be done only after unit has been disconnected from
electrical power and grounding.
Never use a metal or stiff brush to clean the mixer. Never clean the mixer with water hose
or any fluid under pressure.
Do not run the mixer for any extended period of time.
Daily:
The mixer should be cleaned daily. Bowl and agitators should be removed from the mixer
and cleaned in a sink with soapy warm water.
Weekly:
The transmission case and planetary mechanism should be inspected weekly for leak
and damages. Should it become necessary to repack the ball bearings, an authorized
service technician or the manufacturer should be contacted. Use of unproven grease or
oil (lubricant) may lead to damage and void the warranty.
Monthly:
Verify bowl lift track and
mechanism. The bowl lift
track should be lubricated
semiannually, or more
often under heavy usage.
Disconnect the unit from
power supply before
removing the top housing
or apron. The drip cup
should be inspected
periodically for moisture or
lubricant dripping. Remove
the cup and wipe it with a
soft cloth.
Verify oil level inside the
gear box.