User`s manual

Appendix A: Troubleshooting
AXIS StorPoint CD User’s Manual 103
Error Conditions
The following table shows how the front panel indicators show various
error conditions:
* The Network LED will flash when there is network traffic.
** Check the
stat.txt
file in the StorPoint CD’s
config
folder for more information.
*** The CD LED and Network LED flash alternately in this condition.
**** Try setting the DisconnectReselect parameter to
off
.
Status Indicator On
If the Status indicator remains lit after startup, this may indicate an
error. Most likely there is a problem with the SCSI bus or with any of
the connected CD-ROM drives. Make sure all connected drives have
unique SCSI addresses and that only the last drive in the SCSI chain is
terminated.
CD Indicator Off
If the CD indicator remains off when inserting a CD-ROM into a
connected drive, check that the CD-ROM is in a supported format
(High Sierra, ISO 9660, Multisession, ISO 9660 with Rock Ridge or
Joliet extensions). Also check the SCSI bus connectors to ensure that
they are correctly inserted and in good condition.
Event Status LED CD LED Network LED
CD-ROM has incorrect format
or SCSI bus not connected**
OFF Flash Flash*
Faulty network connection OFF OFF
Illegal serial no. Flash Flash Flash
Flash load failed Flash OFF OFF
Token-Ring loopback failure Flash Flash OFF
Token-Ring speed error ON OFF Flash
Error in EEPROM Flash OFF OFF
Error in FLASH PROM Flash OFF Flash
Error in SRAM Flash Flash OFF
Error in DRAM/DIMM Flash OFF OFF
Error in DRAM/DIMM
configuration error
Flash Flash OFF
Software/Hardware
combination error
Flash Flash*** Flash***
Disconnect/reselect drive
error ****
Flash