Technical data

The item nos. below refer to the system diagram on the opposite page.
Item no. Designation Description
1 analog cable shielded, twisted pairs, 3x2x0.25mm
2 shield terminal clamps various sizes
3 mains adapter 24VDC/xA auxiliary voltage supply
4 1EF06 mains filter, manuf. Seidel, single-phase
5 mains cable shielded, 4x1,5 ... 25mm
6 EMC-PGxx PG screwed gland, built into the motor terminal box
7 brake cable shielded, can be trailed, 4x1,5mm
8 BAR860 Ballast resistor, manuf. Seidel
9 digifas™ 7133 to 7150 servo amplifier, manuf. Seidel, various versions
10 ROD/SSI cable shielded, twisted pairs, 4x2x0.25mm
11 resolver cable manuf. Seidel, ready-made, can be trailed
12 EMC-RES-connector component of resolver cable manuf. by Seidel
13 woven tape manuf. Seidel, ready-made
14 ring core ferrite ring, various sizes
15 motor cable manuf. Seidel, can be trailed, shielded
16 3EFxx mains filter, manuf. Seidel, for various currents
17 6SMxx synchronous servo-motor, various frame sizes
18 3L0,5-60 mains choke
Make a selection from our price list. Configure your own tailor-made servo system from
our individual components.
Our applications department is always available to deal with your queries.
The components listed below do not have any decisive effect on the conformance of single-axis
systems to the standards. However, for multi-axis systems item F may need to be shielded,
depending on the length.
A 11 x 0.5mm
, single cores
B PC cable, manuf. Seidel
C line driver (booster)
D Fuses F
and F
E earth lead, 1.5 ... 16mm
F length more than 20cm : shielded cable, 7x10 ... 25mm
length up to 20cm : 5 single cores, 10 ... 25mm
Chapter VI Appendix Page VI - 5
digifas™ 7100 series 01.98
Only under the condition that the system components listed below are used and that the
commissioning instructions in this documentation (Chapter II.2) are followed, can we
guarantee the conformance of the servo amplifier with the following standards for indu
-
strial areas:
EC EMC Directive 89/336/EEC
EC Low Voltage Directive 73/231/EEC
If there is any deviation from these requirements you must provide your own measure
-
ments to demonstrate conformance to the standards.