Technical data

IV.5.3 Commissioning
Our applications department can help you with commissioning.
Preparation
switch off the supply voltages
detach plug X4 from the servo amplifier
check LB1 (final speed), change solder link if necessary
set enable signal to 0V
switch on aux. voltage 25V DC and PC, start operator software BS7200
Setting parameters
set parameter “ROD resolution” to 1024 incr./turn
adjust parameter “Final limit speed” to the setting of LB1
set parameter “I/O” to 1:1 control
set parameter “Ramp +” to 2ms
set parameter “Ramp –” to 2ms
store the parameter set in the EEPROM
switch of the 25V DC aux. voltage
Optimization
connect plug X4 to the servo amplifier, switch on the voltages
optimization : offset adjustment with potentiometer P303
AC gain adjustment with potentiometer P305
continue in the same way as the corresponding description in the BS7200 manual.
IV.5.4 Position of the connectors and control elements - A.4.011.4/27
Page IV - 8 Interfaces and options Chapter IV
01.98 - A.4.011.4/27 digifas™ 7100 series