The maintenance procedures in this list should be performed on a daily
basis. The list includes the procedures to be performed, the specifications
that must be met, and a column for indicating whether the System has
passed each procedure.
Photocopy this list and mark each completed procedure.
Maintenance Technician Name: ________________________
Date: ________________________
Caution: All System operations must be stopped and any Workpieces
removed, before performing these procedures.
Daily Maintenance Procedures
Examine Procedure & Specifications Passed
Level of air pressure in
the Spindle and X-Axis
Read the Air Pressure Gauge on the
Pneumatic Panel at the rear of the
System (see Figure 10-2). If the air
pressure is below 72 psi, adjust the
Regulator located above the Gauge by
pulling the ring up, rotating the dial and
pushing the ring back into place.
Supply of Spindle
cooling water
Stop the flow of cooling water to the
Spindle. Verify that the appropriate
Error Message is received.
Water flow control
Feed cooling water onto the Cooling
Block. Verify that the reading in the
Setup & Diagnostics Workbook meets
process specifications. Verify that the
flow of water from the Cooling Block
Nozzles onto the Blade is constant.
Presence of water
leaks outside the
System
Inspect the floor in the area
surrounding the System for traces of
water. Inspect all external Tube and
hose connections.