Specifications

ADT Model 7100 Semi-Automatic Dicing System Maintenance Manual
Greasing Procedures
P/N 97100-9005-000-14 Ver 06/05
3.4-5
2 Remove the four screws securing the Z Casting Access Panel to the
Z Casting Cover, and remove the Z Casting Access Panel.
3 In the Video Workspace use the left group of arrows to align the
Z Casting Access Panel with the Maintenance Panel.
4 Apply grease to the six grease nipples, three on each side of the
Z Casting. Use waste cloth to wipe off any excess grease.
5 Initialize and operate the newly greased Y and Z Axis, as follows:
a. Click in the toolbar to display the Setup & Diagnostics
workbook.
b. From the Setup & Diagnostics tree, select saw > Dicer >
Axes > Y.
c. In the lower right pane, click Init to initialize the axis, then click
Toggle Self Test. The Y Axis begins moving automatically
between its two limits. Allow the Y Axis to continue moving for
one minute, then click Toggle Self Test again to turn off the
self-test.
d. From the Setup & Diagnostics tree, select saw > Dicer >
Axes > Z.
e. In the lower right pane, click Init to initialize the axis, then click
Toggle Self Test. The Z Axis begins moving automatically
between its two limits. Allow the Z Axis to continue moving for
one minute, then click Toggle Self Test again to turn off the
self-test.
1 Z Casting
2 Grease Nipples
Figure 3-5: Z Casting Grease Nipples
1
2
Note: Press the lever of the Grease Gun three times to feed sufficient grease
into the nipples.