Specifications
Greasing Procedures
Advanced Dicing Technologies Ltd.
3.4-2
is ejected during greasing. If greasing is done in clean-room conditions, use
dust-free waste cloth.
3.4.2 Greasing the X Axis
Grease the X Axis Leadscrew on a monthly basis by performing the
following procedure.
To Grease the X Axis:
1 Open the Left Side Panel by removing the two securing screws.
2 Move the X Axis to the Home position, as follows:
a. Open the Video Workspace.
b. Using the left group of arrows, move the X Axis left till the X Axis
grease nipple is easily accessible for the grease gun.
Note: On a quarterly basis, remove the old grease before applying the new
grease, as described in section 3.4.2.1.
1 Securing
Screws
2 Left Side Panel
Figure 3-1: Left Side Panel
2
1
Note: At this point, the user may want to disconnect the pipes that
supply water and air to the water and air gun. The water and air supply
to the System must be closed.