Installation guide

ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Powering Up/Down Procedures
P/N 97100-9002-000-14 Ver 06/05
3.1-3
3.1.2 Powering Down the System
Powering down is required to perform maintenance on the Model 7100.
Powering down the System every night is not required.
To Power Down the System:
1 Press the Stop>OFF button. The system stops and a pop-up
message appears on the screen:
2 Press the Stop>OFF button a second time (equivalent to clicking Yes
in the pop-up message), the system shuts down. For more details about
the Stop>OFF button, refer to
section 2.1.1.2,
The system powers down in the following order:
1 The computer shuts down
2 The machine turns off
3 The monitor turns off in about 45 seconds after the machine.
The powering down process takes 1 to 1.5 minutes.
3.1.2.1 Lockout/Tagout
To Lockout/Tagout the System:
1 Shut down the main circuit breaker on the right side of the machine.
2 In order to lock the machine in power-off state, lock the main circuit
breaker door.
Note: It is recommended to stop System operation before initiating the power
down procedure.
Note: Wait at least one second between the first button press and the
confirmation.
Danger: Voltage remains in the inlet of the Main Power Unit (MPU) even after
completing the preceding Power Down procedure. Be sure to totally disconnect
the System from the electricity supply before performing maintenance or repair
procedures.
Note: Before powering the system up, make sure that both the computer and
the monitor are powered off (monitor LED is off).