Installation guide
ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Graphical User Interface
P/N 97100-9002-000-14 Ver 06/05
2.2-21
Clicking on an axis button turns the coordinate value on the current axis
into a reference point (zero) as shown in
Figure 2-24.
The Axis buttons turn blue and an "r" (reference) letter appears next to the
Axis letter.
Clicking the central box changes the type of movement, as follows:
F: Moves at the Fast Velocity, as defined in the X and Y Axes
parameters in the Setup & Diagnostics workbook.
S: Moves at the Slow Velocity, as defined in the X and Y Axes
parameters in the Setup & Diagnostics workbook.
P: Moves one pixel at a time.
I: Moves Index by Index along the Y-Axis, using the Index value
specified in the Recipe (relevant only if a Cut Map exists).
Guide Controls
The Guide Control (central Display Control) is used to change the size of
the Guides (Reticle, Teach Area and Search Area) displayed in the FOV.
Clicking the central box toggles the item to be resized, as follows:
S: Search Area
R: Reticle
T: Teach Area
The left and right buttons adjust the width of the selected Guide, while the
up and down buttons adjust the height of the selected Guide.
Figure 2-24: Zeroed Axis Buttons
Note: The Workpiece and the Vision head can be moved along the X and Y
Axes by double-clicking a location inside the FOV.
Note: When the Search Area is Parallel or Dashed, the left and right buttons
are disabled. Only the height can be changed when using these Search Areas.