Installation guide

Recipe Parameters
Kerf Check Limit Parameters
Advanced Dicing Technologies Ltd.
A-38
Kerf Check
Limit
Head1
Center-To-Max
Chip
The maximum distance permitted from the center of
the cut to the tip of the largest chip.
Possible Values (mm):
min = 0, max = 1, Default = 0
Kerf Check
Limit
Head1 Correction
DY Offset
When the Kerf Check finds a dY Offset above this
value, no automatic Y Offset correction is performed
but an error is found. When the Kerf Check finds a dY
Offset below this value, automatic Y Offset correction
is performed.
This parameter only takes effect when Auto Y Offset
Correction is Yes.
Possible Values (mm):
min = 0, max = 1, Default = 0
Kerf Check
Limit
Head1 No
Correction DY
Offset
When the Kerf Check finds a dY Offset below this
value, no automatic Y Offset correction is performed.
When the Kerf Check finds a dY Offset above this
value, automatic Y Offset correction is performed.
This parameter only takes effect when Auto Y Offset
Correction is Yes.
Possible Values:
min = 0, max = 9999, Default = 0
Kerf Check
Limit
Head1 Skew
The maximum offset permitted in the Y-Axis between
the first and last Model found.
Possible Values:
min = 0, max = 1, Default = 0
Kerf Check
Limit
Head1 Top
Chipping
The maximum distance permitted from the lowest
point of a chip to the tip of the largest chip on the
upper-cut edge.
Possible Values (mm):
min = 0, max = 1, Default = 0
Kerf Check
Limit
Head1 Top
Chipping Area
The maximum area permitted for the total chipping
area on the upper edge of the cut.
Possible Values:
min = 0, max = 9999, Default = 0
Kerf Check
Limit
Head1 WMax
The maximum allowed cut width.
Possible Values:
min = 0, max = 1, Default = 0
Kerf Check
Limit
Head1 WMin
The minimum allowed cut width.
Possible Values:
min = 0, max = 1, Default = 0
Table A-17: Kerf Check Limit Parameters
Category Parameter Description