Installation guide
ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Align Parameters
P/N 97100-9002-000-14 Ver 06/05
A-15
Align
Main Model High
Score (%)
The threshold value after which the verification of the
model is not required
Possible Values: 50% - 100%
Should be set to 70%
Align
Main to Sub model
accuracy
It defines the accuracy to accept low threshold model
as a valid model based on the sub model.
Possible values:
1 - 50 µm
Default - 2 µm
Align
Maximum No. of
Iterations
The amount of times the system will repeat the
alignment in order to enter Align - Final Accuracy.
Possible Values:
min = 0, max = 10, Default = 0
Align Recover Option
The action taken by the 7100 if Alignment fails or the
Model is not found.
Possible Values: Manual; Reject
Manual (default): Waits for User intervention, for
example, for the User to find the Model.
Align Settling Time
The amount of time the Workpiece is allowed to dry
before Alignment begins.
Possible Values:
min = 0, max = 20, Default = 0
Align
Spiral Search
Length (X)
The length of the spiral search area within the Index.
Defined per Angle.
Possible Values:
min = 0, max = 50, Default = 5
Align
Spiral Search
Width (Y)
The width of the spiral search area within the Index.
Defined per Angle.
Possible Values:
min = 0, max = 50, Default = 5
Align
Spiral-Index
Search Length (X)
The length of the spiral search area outside the Index.
When the System fails to find a Model, it makes a
spiral search around the area. The parameter is
defined per Angle.
Possible Values:
min = 0, max = 300, Default = 50
Table A-2: Align Parameters
Category Parameter Description