Installation guide

Recipe Parameters
Align Parameters
Advanced Dicing Technologies Ltd.
A-14
Align Index Tolerance
The permitted variation between the index found
during Alignment and the index specified in the
Recipe.
Possible Values:
min =.001, max = 900, Default =.01
Align Initial Focus-Shift
The relative position of the Z-Axis that provides an
acceptable default focus. (This can be used when the
thickness of the Workpiece is changed after
Alignment has been taught. Instead of reteaching
Alignment, the User can use the simpler and faster
process of updating the focus.)
Possible Values:
min = -20, max = 20, Default = 0
Align Initial Theta-Shift
The difference in the Theta Axis position (in degrees)
between the current Workpiece and the taught
Workpiece.
Possible Values:
min = -300, max = 300, Default = 0
Align Initial X-Shift
The difference in the X-Axis position between the
current Workpiece and the taught Workpiece.
Possible Values:
min = -300, max = 300, Default = 0
Align Initial Y-Shift
The difference in the Y-Axis position between the
current Workpiece and the taught Workpiece.
Possible Values:
min = -300, max = 300, Default = 0
Align
Low Alignment
Verification
When set to Yes, the System performs Alignment by
Low Model until the final accuracy value is reached.
It is recommended to set this parameter to Yes, when
the Align Kerf Model is used as the Main Model.
Default value: No
Align
Low Model
Enabled
If set to "Yes", the option to teach and use the Low
Models in the second angle is enabled.
Possible Values: "Yes", "No"
Should be set to "Yes"
Align
Low Model High
Score (%)
The threshold value after which the verification of the
model is not required
Possible Values: 50% - 100%
Should be set to 70%
Table A-2: Align Parameters