Installation guide

Main Subsystems
Advanced Dicing Technologies Ltd.
2.1-2
The ON button powers on the Components and the PC, which then
starts loading the software. When the ON button is pressed, it
lights.
The STOP > OFF button stops the system operation (if pressed
once) and shuts down the System (if pressed twice).
To start the
System up again, press ON and wait for the GUI screen asking for
the User Password.
This button enables the operator to immediately stop any activity in order
to prevent self-injury or damaging the material.
This feature is supported by the Model 7100 Series as follows:
When pressed once, the system stops and a pop-up message appears on
the screen:
When pressed a second time (equivalent to clicking Yes in the pop-up
message), the system shuts down.
When the Stop button is pressed for the first time, the system stops at its
current location in all axes, excluding the Z-axis, which moves up (if stop is
pressed during the first init, the Z-axis also freezes). The user can also
define in the Setup and Diagnostics parameters that the Spindle and the
Cooling Block water should stop when the Stop button is pressed.
In order to resume operation, the system should be activated. Upon
activation, the regular system logic takes effect. For example, if the Stop
button was pressed during:
Any Teach sequence: The process stops. It can be resumed by re-
teaching the whole sequence.
A cutting process: The process stops. It can be resumed by pressing
Auto Run or Full Wafer Cut.
Note: The STOP/OFF button is spring-loaded to always be ready in its "out"
position.
Note: Wait at least one second between the first button press and the
confirmation.