Installation guide

ADT Model 7100 Semi-Automatic Dicing System Operations Manual
UPS Bypass
P/N 97100-9002-000-14 Ver 06/05
10.8-1
10.8 UPS Bypass
The following procedure covers the situations of UPS battery Discharge or
Failure.
This procedure defines the steps that should be taken to bypass the UPS in
the 7100 Software.
To Bypass the UPS in case of its Discharge or Failure
1 Verify that the Windows is UP.
2 Start the 7100.
3 Press Alt+Ctrl+Delete to open the Windows Task Manager.
4 Click the Application Tab.
5Mark "7000 Dicing System" and click End Task (see Figure 10-3).
6 Click End Task in the additional dialog window.
7 Click Start > Settings > Control Panel > Services.
Caution: if the UPS is bypassed the PC may be damaged by a loss of power.
Caution: This process must be finished within 110 seconds.
Figure 10-3: Stopping the 7100 Software