Installation guide
Autoloader
Advanced Dicing Technologies Ltd.
9.1-18
9.1.3.5.2 Recovery After a Severe System Failure
A severe failure, such as the loss of air or water pressure, causes the
system to immediately suspend operation.
The system notifies the user by flashing the red light on the Light, but will
not necessarily display an error message on the screen.
Once the problem has been corrected, the system restarts the programmed
cutting procedure from the first available frame in the Cassette (and not
from the frame that was being processed when the severe failure occurred).
To Recover From a Severe System Failure:
1 Remove the frame that was being processed at the time the failure
occurred. The frame must be removed regardless of its location in the
system.
2 Use the Troubleshooting Flow Diagram given in the Autoloader section
of the Model 7100 Maintenance Manual to isolate the problem and
correct it.
3 In case a error message is displayed, click OK to close it and initiate
the Model 7100.
Otherwise, click Init on the Model 7100 GUI main window.
4 Click Run.