Installation guide
ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Open Loop Theta Accuracy Procedures
P/N 97100-9002-000-14 Ver 06/05
8.4-3
changed angles, the Theta axis may perform slight movements for final
correction of the new position.
It is important to take into account, that Final Accuracy and Maximum
no. of iterations settings depend on the camera magnification. In order to
achieve higher Theta accuracy, set the Maximum no. of iterations to 9
and the Final Accuracy according to the table below:
Note: Using this feature can significantly improve the Theta Axis accuracy. It
should be used only with open loop Theta Axis (cable type).
Camera
Magnification
Final Accuracy
X60 At least 0.08
X120 Up to 0.08
X240 Up to 0.05