8.1.2.4 Load Monitor Baseline Parameters
The Baseline is the load of the Spindle when the blade is not cutting. It
includes the Spindle Idle Load and the drag force of the cooling water. If
the Baseline measurements are taken incorrectly, the Net Load limit
values will be inaccurate.
8.1.2.4.1 Flow Control Stabilization Delay
This parameter is set to ensure that the Baseline measurement taken is
correct once the flow rates have stabilized. There may be a need to increase
the Flow Control Stabilization Delay if the supply line water pressure is
not steady.
8.1.2.5 Load Monitor Control Screen
The Load Monitor control Screen contains certain settings with which the
User controls the variables of Load Monitor.
Table 8-1: Parameters for Cutting
Parameter Name Parameter Description
F Sp High AVG Limit
The highest average load the Load Monitor allows
until the response is triggered.
F Sp Low AVG Limit
The lowest average load the Load Monitor allows
until the response is triggered.
Table 8-2: Baseline Parameters
Parameter Name Parameter Description
F Sp Flow Control
Stabilization Delay
The delay before measuring the Baseline which
allows the System to stabilize the water flow rate
(See
section 8.1.2.4.1).