Installation guide
ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Chuck Change
P/N 97100-9002-000-14 Ver 06/05
7.5-3
To replace a Thick chuck with a Thin one
1 Measure the thickness of the New and Old Chucks.
2 Access Z-Axis parameters: Workbook Workspace > Saw > Dicer >
Axes > Z.
3 Check and decrease the following Z-Axis parameters according to the
measured difference of Chuck thickness:
• Pre Non Contact Height Position
• Calibration Start Position
4 Browse to Chuck screen (Workbook Workspace > Saw > Dicer >
Chuck) and click Chuck Change icon
5 Replace the chuck and lower the NCH or Button device. Use the NCH/
Button Adjustment Bar to level the height device with the chuck top
surface.
6 Follow the Wizard instructions. Click Next to install a new chuck or
Finish to leave the current chuck.
7 Update the Auto-Focus on dicer chuck, as described in section 7.5.2
below.
7.5.2 Reteaching the Focus on the Chuck
To Re-Teach Focus on Chuck:
1 Click in the toolbar to display the Video Workspace.
2 Using the Z/T Axis Controls, manually focus the new Microscope on the
Cutting Chuck.
3 Click to display the Setup & Diagnostics workbook.
4 From the Setup & Diagnostics tree, select saw > Dicer > Axes > Z.
5 In the upper right area of the screen, scroll to the Axis Points category.
Note: When physically replacing the chuck, ensure that the Theta table is
clean.
Note: For Vectus and Fortis series, lower the NCH or Button by lowering the
whole assembly (Open screw on the X-table bracket). For older series, lower
NCH or Button device. Make sure, that the device is not taken out from the
internal O-ring of the device base.
Note: After chuck replacement, set the Calibration Start Position according to
the largest blade and the highest chuck.
Note: It is recommended to perform the Chuck to Non-chuck Height procedure
using a dressed blade.