Installation guide
ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Blade Handling
P/N 97100-9002-000-14 Ver 06/05
7.4-3
• Arrow-shaped cursor - click on a point in the graph to get the Cut
Length and Blade Exposure values
• Cross-shaped cursor - click and drag to zoom in
• Arrowed Cross-shaped cursor - click and drag to move the zoomed
graph
The red line in the graph is the maximum Blade wear or minimum Blade
exposure permitted, and the yellow line is a warning that Blade exposure
has reached a critical level.
These values are specified in the Recipe in the following parameters:
Either,
• Min Exposure Left: The minimum blade exposure permitted before a
blade stops cutting.
• Min Exposure Warn Delta: The minimum blade exposure that
triggers a warning.
or
• Max Wear: The maximum amount of wear permitted on the Blade and
after which the Blade has to be replaced.
• Max Wear Warn Delta: The maximum amount of wear on the Blade
that triggers a warning.
For further information about Blade parameters, see Appendix 3.
7.4.1.1.2 Wear Rate Chart
The Wear Rate Chart displays the relation between the cut length and
Blade wear.