Sample Blade Calibration is performed at the factory and should be carried
out after Spindle adjustment or replacement.
To Perform Sample Blade Calibration
1 Accurately Measure the blade diameter (e.g. using microscope.)
2Go to SetUp > Saw > Cutting Block > Sample Diameter, enter the
blade diameter value in the relevant field and click Save.
3 Click on the Sample Blade Calibration button. The system performs
contact height on the chuck.
4 Wait until the wizard displays a message that calibration height is
completed.
7.3.5 Auto Height Compensation
The Auto Height Compensation feature is used to calculate the rate of
blade exposure and use this information to automatically adjust the blade
height in order to compensate for the exposure.
When this feature is activated, the calculated blade exposure as a function
of cut length is displayed in the exposure graph next to the actual
exposure. In addition, whenever the ADT Model 7100 Semi-Automatic
Dicing System uses the exposure calculation to automatically compensate
for the exposure, a blue caption is displayed on screen (see
Figure 7-5).
Note: Since this procedure is very delicate, it has its own access rights setting.
1 Compensation
Indication
2 Exposure
graphs:
green - actual
blue - calculated
Figure 7-5: Auto Height Compensation
1
2
1